Files
PacketStation/docs/POLICY.md
T

91 KiB
Raw Blame History

Packet Station policy

Who may do what to a packet, and when. This file is written from the code in server/packetstation/policy/. When they disagree, the code is the rule and this file is out of date.

Purpose

The policy is a Python port of the old guard.js. It runs only on the server. Every packet write calls policy.check() inside the write transaction, under the packet row lock. Every packet read returns can, blocked and holder from the same rules, so the screens only show what the server will accept. The Q.C. folder and ITP writes belong to a project or a unit, not to a packet; they call policy.check_scoped() under their own row lock (see "Scoped checks").

The package is pure functions with no I/O:

  • actions.py: the Action enum, the Who predicates, the Rule record and the RULES table.
  • principal.py: Principal, PacketState, principal_from_roles().
  • custody.py: holds(), works_on(), holder_name() and the Who predicates.
  • preconditions.py: the named preconditions and their messages.
  • engine.py: check(), check_scoped(), evaluate(), can() and Decision.

Roles

Every role comes from an AD group (see docs/SECURITY.md). The role strings are admin, clerical, clerical_supervisor, warehouse, warehouse_supervisor, qc, qc_supervisor, pm and shop:<code>:<worker|lead|supervisor>. A person's roles are the union of their groups.

principal_from_roles(user_id, roles, station_limits=(), session_kind="password") builds the policy's Principal:

Field Meaning
admin In PS-Admins. Admin is not membership. It is the bypass rule below.
support The codes among CL, WH and Q.C. the person belongs to, at any level. A supervisor role implies membership.
support_sup The codes among CL, WH and Q.C. where the person is Supervisor.
shop Shop department code to level: 1 worker, 2 lead, 3 supervisor. The highest level wins.
station_limits Station ids a worker is limited to. Empty means any station.
pm Project Management. PM can read every packet and change nothing.
session_kind password or pin.
system visual-feed for the worker. Never set from a session.

A role string that does not parse is ignored.

Custody

Only whoever holds the packet may change it. Everyone else can open it and follow it.

Status Holder
draft Clerical
warehouse Warehouse
ready, review Lead or supervisor of the packet's department
assigned, in_progress Lead or supervisor of the department, or a worker who works on it
qc Q.C.
complete Clerical (data book)
filed Nobody

works_on(principal, state): a member of the packet's department. Leads and supervisors always pass. A worker passes when they have no station limits, or the limits hold the packet's station. START and SUBMIT also need the assigned welder for a worker (see the tightenings).

holder_name(state, dept_name, station_name) gives the text for messages: "Clerical", "Warehouse", "Q.C.", "Clerical (data book)", "the data book (filed)", else the department name, plus " · " while the packet is at a station.

Statuses in workflow order: draft, warehouse, ready, assigned, in_progress, review, qc, complete, filed. SHOP is ready, assigned, in_progress and review. ACTIVE is assigned and in_progress.

Who

Who Passes when
CL, WH, QC A member of that support department, any level
CL_SUP, WH_SUP, QC_SUP Supervisor of that support department
CL_OR_QC A member of Clerical or Q.C.
HOLDER Holds the packet (custody above)
DEPT_LEAD Lead or supervisor in the packet's department
DEPT_SUP Supervisor in the packet's department
WORKS_ON Lead or above in the department, or a worker in the department who is the assigned welder and whose station limits allow the station
CO_VERIFIER Supervisor of the department named in the request: a shop Supervisor for a shop code, WH or Q.C. Supervisor for WH or QC. Clerical never verifies.
ADMIN In PS-Admins
SYSTEM The worker (system is set)

Rule table

from is the set of statuses the action starts from. "any" means any status, with the filed lock applied separately. co hold means an open change order holds the step.

Action Who From To Dept CO hold Preconditions Signature Reason
send_to_warehouse CL draft warehouse no heat_map_answered, drawing_attached
release_to_shop CL draft ready allowed heat_map_answered, drawing_attached, target_dept_given
send_draft_to_qc CL draft qc no heat_map_answered, drawing_attached
wh_send_back WH warehouse draft no reason_given yes
return_to_clerical DEPT_LEAD ready, only when wh_skipped draft no reason_given yes
wh_release WH warehouse ready no yes bom_all_pulled_or_short, heats_recorded
send_back_to_warehouse DEPT_LEAD ready warehouse no reason_given yes
assign DEPT_LEAD ready assigned no welder_set
unassign DEPT_LEAD assigned ready no
pull_back DEPT_LEAD in_progress ready no
start WORKS_ON assigned in_progress no
submit WORKS_ON assigned, in_progress review no yes checklist_complete, welds_recorded, filler_set Submit work to the supervisor
return_to_station DEPT_SUP review assigned no reason_given yes
send_to_qc DEPT_SUP review qc no yes qc_book_spool_location Send to Q.C.
route_from_review DEPT_SUP review ready required yes target_dept_given Route to another department
qc_reject QC qc review no reason_given Q.C. reject yes
qc_accept QC qc complete no yes qc_missing_empty, route_given Q.C. accept
qc_accept_and_route QC qc ready required yes qc_missing_empty, target_dept_given Q.C. accept and route
file CL complete filed no yes vclosed_if_databook File in the data book
admin_reopen ADMIN filed (filed_ok) complete no reason_given Reopen a filed packet yes
edit_header CL draft
edit_drawing_ref CL any
edit_dept CL draft
move_unit CL any
edit_wos CL draft
edit_bom HOLDER draft, warehouse, SHOP
wh_receive_short WH any short_open
edit_heats HOLDER warehouse, SHOP
edit_heat_table HOLDER warehouse, SHOP
edit_welds HOLDER SHOP
edit_checklist HOLDER SHOP
edit_stage_fields HOLDER SHOP
clock HOLDER SHOP
edit_qc QC qc
set_wh_stage WH warehouse
edit_document_set CL any Attach a drawing by hand (attach only)
doc_add CL_OR_QC any
doc_remove CL_OR_QC any
rev_approve CL_SUP draft reason_given Approve the M-Files revision yes
set_vclosed CL complete, only when routed_to is databook
set_databook_at CL_OR_QC any (filed_ok)
remove CL draft reason_given yes
co_issue CL any Issue a change order
co_approve CL any Approve a change order
co_reject CL any reason_given Reject a change order yes
co_hold_toggle CL any
co_verify CO_VERIFIER any Verify a change order for the department
qc_doc_add CL_OR_QC no packet (scoped)
itp_start QC no packet (scoped)
itp_line_sign QC no packet (scoped)
itp_line_unsign QC no packet (scoped)
itp_edit_line QC no packet (scoped)
itp_block_sign QC no packet (scoped) Sign an ITP block
itp_block_unsign QC no packet (scoped)
itp_sign_off QC no packet (scoped) Sign off the ITP
itp_reopen QC_SUP (Admin through the bypass) no packet (scoped) reason_given yes
vis_update_draft SYSTEM draft
vis_retire_draft SYSTEM draft
vis_open_co SYSTEM any but draft and filed
vis_auto_release SYSTEM draft warehouse heat_map_answered, drawing_attached

A holder of the packet who is not in the warehouse receives a short through edit_bom (see "Receive by custody").

The vis_* actions are system only. People can never do them, and the worker can do nothing else.

The Q.C. folder and ITP actions ("no packet (scoped)") belong to a project or a unit, not to a packet. They are checked with check_scoped() (see "Scoped checks"), never with the packet status, custody or the filed lock.

qc_reject takes an NCR number in place of the reason text (see "Q.C. (phase 6)", "Reject").

Preconditions

Each precondition is a named predicate over the packet state and the request input. They are never bypassed, Admin included. The first one that fails gives the message.

Name Passes when Message
heat_map_answered heat_map is yes or no Say whether this packet needs a heat map.
drawing_attached a drawing is attached Attach the drawing first.
bom_all_pulled_or_short every line not marked n/a is pulled or has an open short Pull every material line or mark it short first.
heats_recorded no line needs a heat: every line that is not N/A, not a sub-assembly, is pulled and issued pieces has a heat Scan or type the heat number of every pulled line first. Use N/A for a part with no traceability.
short_open at least one BOM line has an open short (the old whCanReceive) No part is short on this packet.
welder_set (input) the request gives station_id and welder_id Pick a station and a welder.
checklist_complete every key of the department checklist is done Finish the checklist first.
welds_recorded at least one weld in the packet's current department, in a weld department Record at least one weld first.
filler_set filler metal entered, in a weld department Enter the filler metal first.
qc_book_spool_location (input) book and spool confirmed and a location given Confirm the book and the spool, and give the location.
qc_missing_empty the Q.C. record has nothing missing Q.C. still needs: (the list).
reason_given (input) a reason of at least 8 characters after cleaning Give a reason of at least 8 characters.
vclosed_if_databook routed to Shipping, or closed in VISUAL Close the job in VISUAL first.
co_staged_if_dwg_change (input) no drawing change, or the new drawing is staged (phase 3) Stage the new drawing for the change order first.
route_given (input) routed_to is databook or shipping Choose Data Book or Shipping.
target_dept_given (input) a shop department different from the packet's; from a draft any shop department Choose a department. / Choose a different department.

"(input)" marks a precondition that reads request input, not packet state. can() skips those.

Order of checks

check(principal, state, action, *, extra={}, it_reason=None) -> Decision runs these in this order and stops at the first failure:

  1. Removed. A removed packet refuses everything, Admin included. Code removed.
  2. Status. The status must be in the rule's from set. RETURN_TO_CLERICAL also needs wh_skipped. SET_VCLOSED also needs routed_to databook. An unknown status fails here too. Code wrong_status.
  3. Change-order hold. A held action refuses while an approved change order waits for verification, or a pending one is on hold. Admin included. Code co_hold, with the hold text.
  4. System. A system-only action refuses every person (system_only). The system principal passes only system-only actions (forbidden).
  5. Admin bypass. An admin who is not allowed by the rule's Who passes who and custody when an IT reason of at least 8 characters is given. Without one the code is it_reason_required. SET_DATABOOK_AT needs no reason. The decision is marked admin_bypass, and the write marks the log row as an IT edit.
  6. Filed lock. A filed packet refuses everything except SET_DATABOOK_AT and ADMIN_REOPEN, Admin included. Code filed: "This packet is filed and locked. IT can reopen it if a correction is needed."
  7. Who and custody. Code forbidden. For a step: "Your access doesn't allow this step." For an edit: "Your access doesn't allow changing (what) on this packet. It's with (holder) right now." PM fails here for everything.
  8. Preconditions, in rule order, never bypassed. Code precondition with the message, or reason_required when the missing piece is the rule's reason, so the screen can ask for one.

Decision carries ok, code, why, admin_bypass, signature (the meaning text when the rule needs one) and, in read mode only, reasons.

The packet API answers 403 with the code for most failures, and 400 for it_reason_required and reason_required.

Scoped checks

check_scoped(principal, action, *, extra=None, it_reason=None) -> Decision runs the same steps as check() without a packet, for the actions that belong to a project or a unit (the Q.C. folder and the ITP):

  1. System. A system principal fails (forbidden). A system-only action fails every person (system_only).
  2. Admin bypass. An admin not allowed by the rule's Who passes with an IT reason of at least 8 characters, else it_reason_required. The decision is marked admin_bypass.
  3. Who. Code forbidden, "Your access doesn't allow this."
  4. Preconditions, the input ones in rule order. reason_given fails as reason_required.

There is no removed, status, change-order hold, filed lock or custody step: there is no packet and no holder. The ITP and Q.C. folder writes call it inside their own transaction, under the itps row lock or the lock on the Q.C. document being replaced. They never take a packet row lock, because they change no packet and must not wait on, or block, the packets of the unit.

Signatures

These actions need a signature: submit, send_to_qc, route_from_review, qc_reject, qc_accept, qc_accept_and_route, file, admin_reopen, edit_document_set (attach only), rev_approve, co_issue, co_approve, co_reject, co_verify, itp_block_sign and itp_sign_off. The rule's signature text is the meaning that is signed.

The request carries sign: {factor, secret}. The write pipeline calls the phase 1 helper packetstation.auth.signatures.sign() inside the same transaction, after the policy passes. It checks the PIN or domain password against the session's own user. A PIN works in any session. It logs the attempt and applies the five-strike PIN disable and the three-strike session end. It writes an append-only signatures row with the user, session, account, display name, session kind, factor, action, meaning, packet, subject and a sha256 over the canonical JSON of what was signed (the action, the packet id, the expected state and the request fields). The packet_transitions and packet_log rows point at it.

Concurrency

  • Workflow steps are compare-and-set on expect: {status, dept} under the packet row lock (SELECT ... FOR UPDATE). When the packet moved on, the answer is 409 stale_step "Someone else already took this step." with the current status, department and version. There is no packet version check on a step, so a weld edit never blocks a send. Side effects run in the same transaction.
  • Keyed child rows (BOM lines, Q.C. inspections, stage fields, welds, heat tags) take If-Match: <row_version>. A mismatch is 409 row_conflict with the current row.
  • Numbers for welds, heat tags, pages and change orders come from counters on the packet row under the row lock, so concurrent adds never collide.
  • Header scalars use field-level compare-and-set: the body sends set and base. A key whose base differs from the current value is 409 field_conflict with the current value. A key with no base is written as is.
  • Work orders are a draft-only full replace with If-Match on the packet version.
  • Shorts and change-order actions are state compare-and-set. Checklist keys are written one key at a time. The heat table position is an idempotent upsert. A change-order verification is an insert, so a second one is "already verified".
  • ITP lines are approved under the itps row lock, with a state check and an optional If-Match: <row_version>. ITP header fields use the same set and base field compare-and-set as packet headers.
  • Append-only tables never conflict: packet_transitions, packet_log, qc_history, short_receipts, project_renumbers, itp_rejects, itp_log, print_log and co_verifications. Triggers refuse UPDATE, DELETE and TRUNCATE, and the app role has no grant for them.

Reads: can, blocked and holder

Every packet read returns:

  • can: the actions that pass now. Input-only preconditions are skipped, because they are what the user gives with the step.
  • blocked: the actions that pass who and custody but fail a state precondition or the change-order hold, with every reason. The screen shows the control disabled with the reason.
  • holder: holder_name() for the packet.

can(principal, state, assume_it_reason=True) -> (list[Action], dict[Action, list[str]]). For an admin the IT reason is assumed, so the list shows what the admin may do once they give one. evaluate(principal, state, action) returns the read-mode decision with admin_bypass set, so the screen knows to ask for the reason. System-only actions are never listed. CO_VERIFY needs a department in the request, so it is not listed; the change order list says which departments the person can verify.

Warehouse (phase 4)

Stages

The warehouse stage is packet_wh, separate from the packet status. SET_WH_STAGE (WH, status warehouse) moves it, compare-and-set on expect_stage (409 stale_step when it moved on).

From To
incoming pulling, hold
pulling pulled, hold
hold pulling
pulled pulling

A move to the same stage, or one not in the table, is 409 wh_transition. A packet with no packet_wh row is at incoming. The first Pulled tick on a line while the stage is incoming or on hold starts pulling by itself (auto true).

Hold reasons

A closed set, checked on the server:

  • Waiting on material (not in stock)
  • Waiting on purchasing / PO
  • Question for engineering or clerical
  • Drawing / BOM problem
  • Other

Any other text is 400 invalid_reason "Pick one of the hold reasons." "Other" needs a note, else 400 reason_required "Say what it's waiting on." The note is cleaned and cut to 200 characters.

Short reasons

A closed set, checked on the server:

  • Not in stock
  • On order
  • Back-ordered
  • Damaged / rejected
  • Wrong part received
  • Needs cutting / prep
  • Other

Any other text is 400 invalid_reason "Pick one of the short reasons." A short has a quantity from 1 to the line quantity, a reason, an optional PO or requisition, an optional expected date, an optional note, and the optional heat of the pieces that were pulled (never on an N/A line). Opening, editing and clearing a short is edit_bom, so the holder decides. In practice that is the warehouse.

The release gate

WH_RELEASE checks two preconditions, in this order:

  1. bom_all_pulled_or_short: every line not N/A is pulled or has an open short.
  2. heats_recorded: no line needs a heat. A line needs a heat when it is not N/A, not a sub-assembly (sub is Y; its heat is on its own packet), is pulled, has issued more than 0 and has no heat.

Both are state preconditions, so blocked.wh_release lists the failing message and the screen shows Release disabled with it. Heat numbers are checked against the old pattern: letters, numbers, space . / # _ - only, up to 40 characters, starting with a letter or a number. A bad heat is 422 invalid_heat.

Receive by custody

Receiving short parts (POST .../bom/{item}/short/receipts) picks its action from the person:

  • A member of the warehouse (WH in support) receives through WH_RECEIVE_SHORT, in any status but filed, while the line has an open short. The warehouse does not need to hold the packet.
  • Anyone else receives through EDIT_BOM, so only the holder may: the lead or supervisor of the department that has the packet, Q.C. at Q.C., Clerical in draft.
  • Everyone else is refused by the policy (403 forbidden).

The warehouse still cannot change any other field of a packet it no longer holds. EDIT_BOM stays the holder's. A receipt needs a heat unless the line is N/A, and its quantity is 1 to what is still open.

MTR files

The MTR on a line must be an asset whose type is PDF, PNG or JPEG. Anything else, or an asset that is not there, is 422 invalid_asset. Clearing the MTR is allowed.

Packet log texts

The action column of packet_log for each warehouse write. {item} is the BOM item number.

Write action note
Heat typed or scanned Heat recorded · item {item} the heat
Heat cleared Heat cleared · item {item}
Pulled ticked Pulled · item {item}
Pulled unticked Pulled undone · item {item}
N/A ticked Marked N/A · item {item}
N/A unticked Traceable again · item {item}
Issued only Issued qty changed · item {item} {issued} of {qty}
Location only Location set · item {item} the location
Several fields Line changed · item {item}
MTR attached MTR attached · item {item}
MTR removed MTR removed · item {item}
Short opened Short recorded · item {item} {qty} of {need} short · {reason} · {ref} · ETA {eta}, parts present only
Short edited Short updated · item {item} the same as recorded
Not short after all Short cleared · item {item}
Short received Short received · item {item} {qty} pc · heat {heat} · {still} still short or ... · short closed, then · packet {status} (lower case) and in {station} when at a station
Stage incoming to pulling Warehouse: Started pulling
Stage to hold Warehouse: Put on hold {reason} · {note}
Stage pulling to pulled Warehouse: Marked pulled, ready for production
Stage hold to pulling Warehouse: Pulling resumed
Stage pulled to pulling Warehouse: Back to pulling
wh_release Released to supervisor, or Released to supervisor with {n} short when shorts are open {heats} heats recorded, plus · SHORT: item {item} ×{qty_open} ({reason}), ... when shorts are open
wh_send_back Sent back to Clerical the reason

When a Pulled tick starts pulling by itself, there is no separate stage row in the log: the line's own row gets · started pulling or · pulling resumed on its note. Every write above also writes its audit row through the write pipeline, with detail.item, wh_from and wh_to as before, and detail.qty on short writes.

Shop (phase 5)

Who takes each step

Action Who From Notes
assign Lead or supervisor of the packet's department (DEPT_LEAD) ready Station and welder checked at assign time (below)
unassign DEPT_LEAD assigned Clears station and welder, folds the clock
pull_back DEPT_LEAD in_progress Clears station and welder, folds the clock
start Lead or supervisor of the department, or the assigned welder within their station limits (WORKS_ON) assigned Starts the clock
submit WORKS_ON assigned, in_progress Stops the clock. Signature "Submit work to the supervisor"
return_to_station Supervisor of the department (DEPT_SUP) review Reason
send_to_qc DEPT_SUP review Signature "Send to Q.C.". Opens the inspection
route_from_review DEPT_SUP review Signature "Route to another department". Closes the stage and opens one in the target department
send_back_to_warehouse DEPT_LEAD ready Reason
return_to_clerical DEPT_LEAD ready, only when wh_skipped Reason

A worker who is not the assigned welder cannot start or submit. Neither can the assigned welder when their station limits leave out the packet's station. Every step sends expect: {status, dept}, so a stale screen gets 409 stale_step "Someone else already took this step."

Assign checks

ASSIGN checks the station and the welder on the server, at assign time:

Check Refusal
The station is an active station of the packet's department 422 invalid_station
The welder is an active user with a shop role (worker, lead or supervisor) in the packet's department 422 invalid_welder "Pick a welder in this department."
A worker with station limits (no lead or supervisor role in the department) is limited to the chosen station 422 station_limit "{name} is limited to {station names}."
A stamp in the body matches the stamp pattern 422 invalid_stamp

The stamp in the body overrides the user's welder_stamp for this assignment. Without it, the user's stamp is used. The packet and the stage row both get the station, the welder and the stamp. GET /api/departments/{code}/people gives the assign sheet its welder list, with each person's level and station limits.

The lead's review

A lead holds a packet in review (see "Custody"), but return_to_station, send_to_qc and route_from_review are the supervisor's. The server refuses them to a lead with 403 forbidden. The screen shows the lead the review read-only: "A supervisor for 03 Weld Parts reviews it and sends it on."

Preconditions on the shop steps

Step Precondition Passes when Message
assign welder_set (input) the request gives station_id and welder_id Pick a station and a welder.
submit checklist_complete every key of the department's checklist is done Finish the checklist first.
submit welds_recorded at least one live weld whose dept_code is the packet's current department, in a weld department Record at least one weld first.
submit filler_set filler metal entered on the open stage, in a weld department Enter the filler metal first.
send_to_qc qc_book_spool_location (input) book and spool confirmed and a location given Confirm the book and the spool, and give the location.
return_to_station, send_back_to_warehouse, return_to_clerical reason_given (input) a reason of at least 8 characters after cleaning Give a reason of at least 8 characters.
route_from_review target_dept_given (input) a shop department different from the packet's Choose a department. / Choose a different department.

welds_recorded counts only the current department's welds. After a route, the new department needs a weld of its own before it can submit. The welds from earlier departments are carried marks (see SCHEMA.md, "Carried marks").

Change-order hold

An open change order holds these steps: WH_RELEASE, SUBMIT, SEND_TO_QC, ROUTE_FROM_REVIEW, QC_ACCEPT, QC_ACCEPT_AND_ROUTE and FILE. It does not hold ASSIGN, START, the clock or the edits, so the shop keeps working while the departments verify. A change order is open when it is approved with departments still to verify, or pending with hold on (v_open_cos).

The hold text (the co_hold refusal and the blocked reason):

Change order Text
Pending, with hold CO-2: Clerical is reviewing a change from VISUAL. Held until Clerical approves or rejects it.
Approved, departments pending Change order CO-2 must be verified first by: 03 Weld Parts, 09 Hydro.

With several open change orders, the texts are joined by a space, one sentence each. The id is CO-<co_no> everywhere.

Change-order verification

CO_VERIFY is the supervisor of the department named in the request: a shop Supervisor for a shop code, the WH or Q.C. Supervisor for WH or QC. A lead cannot verify (403 forbidden). Clerical never verifies. Each verification needs a signature ("Verify a change order for the department") and is an insert into co_verifications. A second one for the same department is 409 already_verified. A department the change order does not need is 422 invalid_dept. A verification cannot be withdrawn.

The required departments on approval are the departments the change touches, without Clerical and PM. A minor change order needs none.

The clock

CLOCK is the holder's in the shop statuses. The ops are start, pause and resume. An op in the wrong state is 409 clock_state. The server keeps the time with the database clock. No request sets the elapsed time. START starts the clock when it is not running. SUBMIT stops it. UNASSIGN and PULL_BACK fold the running time in, so the clock freezes. See SCHEMA.md, "The clock".

Marks on the drawing

Welds (EDIT_WELDS), heat tags (EDIT_HEATS) and the heat table (EDIT_HEAT_TABLE) follow the rule table: the holder in the shop statuses, and for heat tags and the heat table also the warehouse while it holds the packet. The server hands out W<n> and H<n> from the packet counters under the packet row lock.

A VOID sheet refuses marks. A new weld or heat tag on a voided page, or a move of one already there, is 422 void_page "This sheet is VOID. Mark the current sheet." The marks on a void page stay and are shown, but cannot be edited.

Heat map borrowing

A packet borrows a sibling's heat map when all of these hold (the old heatSrc):

  • It has no heat map of its own: no heat table placement and no heat tag.
  • It has no raw material of its own: every BOM line is N/A or a sub-assembly, or the BOM is empty.
  • It has a drawing.

The sibling is a live packet in the same unit, with a different id and the same drawing (compared upper-case with white space removed), that has a heat map. The same rev is preferred, then the oldest. The read model gives it as heat_src. It is read-only: nothing on it can be written through the borrowing packet. The screen says "Heat map from on this unit (same drawing). Record heats there."

Shop screens

  • GET /api/shop/board covers the shop departments where the person is lead or supervisor. Admin sees every active shop department. A department outside that scope is 403 forbidden. A person who leads no department gets 403 forbidden "You do not lead a department." The change order list also shows open change orders anywhere that wait on one of the person's departments.
  • GET /api/shop/stations lists the stations the person may pick for the Stall screen: every station of their shop departments at any level, cut to their station limits for a worker. Admin gets every station.
  • GET /api/shop/stall?station_id= is 403 for a station not in that list. Admin passes.

Presence

The packet page shows who else has the packet open. Presence comes over SSE and carries the user id, display name, screen and packet id only. Phase 8 adds the role and the time the person arrived, and drops locked sessions (see "Phase 8: Project Management, find bar, presence").

History texts

The action and note columns of packet_log for each shop write. A department is shown as code and name (03 Weld Parts), except in the verify text, which uses the name only. The station name is as stored (Stall 3).

Write action note
assign Sent to Stall 3 Andy Welder [75] (the stamp in brackets when set)
unassign Taken off Stall 3
pull_back Pulled back from Stall 3
start Work started Stall 3
submit Submitted to supervisor 4 welds · 1.5 h
return_to_station Returned to Stall 3 the reason
send_to_qc Sent to Q.C. Spool at Bay 2 · note
route_from_review Routed to 09 Hydro Supervisor, Q.C. skipped · from 03 Weld Parts
send_back_to_warehouse Sent back to the warehouse the reason
return_to_clerical Sent back to Clerical the reason
Weld added Weld W4 marked Fillet 5/16" · items 1 + 2 · L662001 #1
Weld edited Weld W4 changed the changed fields, type Groove · items 1 + 3
Weld moved (position only) Weld W4 moved
Weld removed Weld W4 removed the reason
Heat tag Heat tag H2 placed, Heat tag H2 changed, Heat tag H2 moved, Heat tag H2 removed item 3
Heat table placed Heat table placed on drawing the page's dwg, else sheet 2
Heat table moved Heat table moved the same
Heat table resized Heat table resized A+ or A- and the new size, A+ 1.15
Heat table removed Heat table removed from drawing the same
Heat table copied on a change order Heat table copied to new sheet from the VOID copy, check its position on the new revision
Checklist Checked: <item text>, Unchecked: <item text>
Stage fields Weld record changed the changed fields, filler ER70S-6 · filler lot 1234
Clock Clock started, Paused, Resumed
Change order issued Change order CO-2 issued
Change order approved Change order CO-2 approved
Change order rejected Change order CO-2 rejected the reason
Change order hold Change order CO-2 holds the packet, Change order CO-2 no longer holds the packet
Change order verified Change order CO-2 verified by Weld Parts note · still waiting on Hydro, or note · change order fully verified

The submit hours are the stage's clock_elapsed_ms after the stop, with one decimal.

Q.C. (phase 6)

Who inspects

Q.C. holds a packet in status qc. EDIT_QC (QC, status qc) covers every write to the open inspection: the check items, the visual result per weld, the NDE fields, hardness, the inspector name, the stamp and the notes. A write with no open inspection is 409 no_inspection.

Write Endpoint Concurrency
One check item PUT /api/packets/{id}/qc/checks/{key} {done} one key by jsonb_set under the packet row lock, no If-Match. Unknown key 422 invalid_key.
One weld's visual result PUT /api/packets/{id}/qc/welds/{no} {result?, note?} one weld by jsonb_set. The weld must be live on the packet (422 invalid_weld). result is accept, reject or empty.
The other fields PATCH /api/packets/{id}/qc {set, base} field-level compare-and-set over inspector, stamp, nde_method, nde_result, nde_report, hardness, notes; 409 field_conflict with the current value.

nde_method must be one of None required, RT, UT, MT, PT (422 invalid_field "Pick an NDE method from the list."). nde_result is empty, Acceptable or Rejectable. Setting the method to None required clears the result and the report number. The phase 2 flat body (with If-Match on the inspection's row_version, merging checks and weld_exam) still works; a body with set selects the field compare-and-set. The NDE rules apply to both. Hardness is labelled Hardness (NACE) when the packet's WPS contains NACE. The server computes this; no request sets it.

Accept

Two actions accept. Both are Q.C. from status qc, held by an open change order, gated by qc_missing_empty, and signed.

Route Action Body Result
Clerical – Data Book qc_accept routed_to: "databook" complete, routed to the data book
Shipping qc_accept routed_to: "shipping" complete, routed to Shipping
A shop department qc_accept_and_route dept: "09" ready in that department, a new stage opened

The signature meanings are "Q.C. accept" and "Q.C. accept and route". The accept closes the inspection into qc_history and closes the stage with the inspection as its qc_snapshot. The note in the log counts every live weld of the packet.

What Q.C. still needs

qc_missing_empty reads the list built by checklists.qc_missing(). Its message is Q.C. still needs: followed by the parts joined by , and a full stop. blocked.qc_accept and blocked.qc_accept_and_route carry it, so the screen shows Accept disabled with the reason.

Part When
3 inspection items that many check items are not done
2 welds without a visual result that many live welds have no accept or reject
a rejected weld (reject the packet instead) any weld is rejected
NDE result an NDE method other than None required is set and the result is not Acceptable
inspector name the inspector is empty

Reject

qc_reject is Q.C. from status qc back to review, signed ("Q.C. reject"). It takes a reason, an NCR number, or both:

  • An NCR number goes through validate_ncr: trimmed, upper case, then the pattern NCR- four digits - four digits. A bad one is 422 invalid_ncr "Enter an NCR number like NCR-2026-0021."
  • The reason checked by reason_given is the NCR alone (NCR-2026-0021) when no text is given, else NCR-2026-0021 · <reason>. So an NCR number stands in for the reason, and the text has no minimum when an NCR is given.
  • With neither, the answer is 400 reason_required with the rule's message. A reason without an NCR needs 8 characters.

The reject stores the NCR on the inspection, sets the packet's return_note to the reason, and closes the inspection into qc_history at once. The packet in review has no open inspection; the read model gives the reject as qc_last, and the screens show the "Q.C. rejected" callout from it. The supervisor's next send to Q.C. opens a fresh inspection.

The change-order hold applies to both accepts and to file. It does not apply to the reject: Q.C. can always send a packet back.

The NCR link is https://ncr.pescoinc.biz/ncrs/<number>. domain/ncr.py validate_ncr is the hook for checking the number against pesco-ncr. Today it accepts any well-formed number. The check against pesco-ncr is a later phase.

Packet documents

DOC_ADD and DOC_REMOVE are Clerical or Q.C. (CL_OR_QC), in any status but filed (the filed lock applies).

  • POST /api/packets/{id}/docs {asset_id, kind, title?, note?}. kind is one of the nine kinds (see SCHEMA.md, "Packet documents"); any other is 422 invalid_kind "Pick a document type from the list." The asset must be a PDF, PNG or JPEG (422 invalid_asset). The title defaults to the kind's label and is up to 160 characters. The note is up to 300 characters.
  • DELETE /api/packets/{id}/docs/{doc_id} {reason} takes a document out of the data book. The reason needs 3 characters after cleaning (400 reason_required "Say why it comes out of the data book."). The row is kept with who, when and why. A second take-out is 409 already_removed.

Drawings are never packet documents. They come from M-Files or the hand attach only.

Q.C. folder documents

QC_DOC_ADD is Clerical or Q.C. (CL_OR_QC), checked with check_scoped(). POST /api/qc/docs {project_id | unit_id, type, title?, rev?, note?, asset_id, replaces?, it_reason?}:

  • Exactly one of project_id and unit_id (422 invalid_request).
  • type is one of ITP, WPS / PQR, NDE procedure, Hydrotest procedure, PMI / material, Calibration certificate, Customer spec, Other (422 invalid_type "Pick a document type from the list.").
  • The asset must be a PDF, PNG or JPEG (422 invalid_asset). Limits: title 140 (defaults to the type), rev 12, note 600.
  • replaces files a new revision. The replaced row must be a current document of the same folder (422 invalid_replace). One that already points at a newer row is 409 already_superseded. The old row is kept and points at the new one. Nothing is deleted.

Reads (GET /api/qc/home, /api/qc/folders, the project and unit folder reads) need any signed-in session. PM reads and changes nothing.

Clerical may add Q.C. folder documents. The old build allowed Q.C. and Admin only. This is wider than the old build; Seth can narrow it to QC.

The ITP

Each unit has at most one digital ITP, started from the code template ITP_Generation_Revised_2 and frozen at start. Reads (GET /api/units/{unit_id}/itp) need any session. Every write runs check_scoped() with its action, then finds the ITP (404), then refuses a complete one (409 itp_complete), locks the itps row, bumps itps.version once, and writes one itp_log row per change, one audit row for each (itp.<action value>, so itp.itp_start, itp.itp_line_sign; subject itp; detail {text, note, unit_id}, plus signature_id on a signed one) and a change event, in one transaction. Block sign and sign-off check their gates before the signature, so a refused step costs no PIN attempt, and check them again under the lock.

Every line and block row is made at start. A Q.C. user's packet read still lists the scoped actions in can; they mean nothing on a packet.

Action Who Endpoint Gate
itp_start QC POST /api/units/{unit_id}/itp 409 itp_exists when the unit has one
itp_edit_line QC PATCH /api/itps/{id} (header), PATCH .../lines/{key}, POST .../sections/{n}/na, POST .../lines/{key}/reject, POST .../lines/{key}/ncr, PATCH .../blocks/{key} see below
itp_line_sign QC POST /api/itps/{id}/lines/{key}/sign the line is not approved (409 already_signed) or N/A (409 line_na); a rejected line needs its NCR (409 ncr_required "Enter the NCR # before approving this line.")
itp_line_unsign QC POST /api/itps/{id}/lines/{key}/unsign the line is approved (409 not_signed); only the inspector who initialed it, or an admin (403 forbidden "Only the inspector who initialed this line, or an admin, can remove it."); refused while the block is signed (409 block_signed "Undo the section signature first.")
itp_block_sign QC, signature "Sign an ITP block" POST /api/itps/{id}/blocks/{key}/sign every line of the block done (409 block_not_ready "Every line must be initialed or N/A first."); not already signed (409 already_signed)
itp_block_unsign QC DELETE /api/itps/{id}/blocks/{key}/sign the block is signed (409 not_signed); the signer or an admin (403 forbidden "Only the inspector who signed this block, or an admin, can remove it."); clears the signature and keeps the block's fields
itp_sign_off QC, signature "Sign off the ITP" POST /api/itps/{id}/signoff every block signed (409 blocks_unsigned "Every section must be signed first.")
itp_reopen QC_SUP, or an admin through the bypass POST /api/itps/{id}/reopen {reason, it_reason?} a reason of 8 characters; the ITP is complete (409 itp_open "The ITP is open already."). An admin who gives no it_reason has the reason used as both.

Line approval is a compare-and-set: the itps row lock, the state check above, and an optional If-Match: <line row_version> (409 row_conflict). Approval sets result approve, by, at and the initials (the first letter of each word of the display name, upper case, at most three). Unsign clears the result, the approver, the time and the initials, so the line is open again. The line's ncr and every itp_rejects row stay.

The itp_edit_line writes:

  • Header (no, client, pname, pno, po, unit): field compare-and-set with {set, base} (409 field_conflict), 120 characters each. no cannot be empty (422 invalid_field).
  • Line details: na is refused on an approved line (409 already_signed) or one with an open reject (409 line_rejected). cust_code is one of R, R/AU, AU, W, H, NA, or empty for the template's (422 invalid_field "Pick a customer code from the list."). cust_by 80, note 500. cust_at defaults to today when a name is given. A change that changes nothing writes no log and no version.
  • Section N/A: sets or clears N/A on every line of the section. Marking N/A is refused when any line of the section is approved (409 already_signed) or has an open reject (409 line_rejected).
  • Reject: refused on a line that is approved (409 already_signed), N/A (409 line_na) or already rejected (409 line_rejected). The NCR is optional and validated when given. An itp_rejects row (kind reject) is added.
  • NCR entered later: the line must have an open reject without an NCR (409 no_open_reject). An itp_rejects row (kind ncr) is added.
  • Block fields: qn 40, remarks 400, cust_name 80, cust_at (today when a name is given), cust_clear clears the customer entry. An empty cust_name without cust_clear is 422 invalid_field "Enter the customer rep's name." No signature.

A write to a complete ITP, other than the reopen, is 409 itp_complete "The ITP is signed off and locked. An admin can reopen it." The sign-off sets status complete and calls pdf.itp.file_signed_itp_pdf(), which builds the signed ITP PDF (phase 7). The sign-off sets signoff_asset_id and files a qc_docs row on the unit (type ITP, auto), superseding any earlier automatic ITP document of the unit. A PDF that cannot be built answers 500 itp_pdf_failed and nothing is signed off. A reopen sets status open with the reason. Block and line signatures stay; the inspector undoes what must change.

ITP actions never look at a packet. A filed packet in the unit does not lock the ITP, because the ITP belongs to the unit (the phase 5 follow-up, open question 28).

Blocks

A signature block closes at every template section marked to sign, and covers the sections since the last block. The template gives blocks 3 (sections 1 to 3), 4, 5, 6, 7, 8 and 9 (the final block). A line is done when it is N/A or approved. A block is ready when every line in it is done, so a block of N/A lines only can be signed.

Hold points

A hold code is H or W, alone or after a slash (R/H), on the PESCO code or the customer code (the line's own customer code when set, else the template's). An open hold point is a line with a hold code that is not done, or any rejected line.

The packet read gives itp_hold while the unit's ITP is open: the open hold and rejected points, filtered by the packet's department page group. It is a warning only. No precondition reads it, and no step is blocked by it. Q.C. and the shop check with each other before moving past a point.

Department Pages it sees
01, 02, 03, 04, 05, 10 WP (Weld Parts)
06, 07, 13 C (Code)
09 WP and C
08, 11, 12, 14 FA (Final Assembly)
CL, WH, QC, or an unknown code every page

Log texts

The action and note of packet_log for each Q.C. packet write.

Write action note
Check ticked Q.C. checked: <item text>
Check unticked Q.C. unchecked: <item text>
Visual result set VT accept · W3, VT reject · W3 the note when given
Visual result cleared VT cleared · W3
Weld note only Q.C. record changed W3 note
NDE method NDE method: RT, NDE method: - when cleared
NDE result NDE result: Acceptable, NDE result: - when cleared (no line of its own when None required cleared it)
Other Q.C. fields Q.C. record changed the changed fields, inspector Quinn QC · stamp Q1 · hardness 198 HB · report RPT-1 · notes changed (<field> cleared, notes cleared)
Flat-body checks or weld exam merge Q.C. record changed
qc_accept to the data book Q.C. accepted → Clerical – Data Book Quinn QC [Q1] · 3 welds VT accepted, plus · RT Acceptable when an NDE method other than None required is set, plus · <note> when the step carries a note
qc_accept to Shipping Q.C. accepted → Shipping the same
qc_accept_and_route Q.C. accepted → 09 Hydro Quinn QC [Q1] · from 03 Weld Parts
qc_reject Q.C. rejected → supervisor NCR-2026-0021 · <reason> · welds W1, W3 (parts present only; the rejected welds by number)
Document added Document added <label> · <title> · <file name>
Document taken out Document taken out of the data book <title> · <reason>

One PATCH that changes several kinds of field writes one line for each. The arrow and the en dash in Clerical – Data Book are the old build's texts. The stamp shows in brackets only when set. The inspector is the inspection's inspector field.

The action and note of itp_log (and the audit row's detail.text) for each ITP write. Dates are M/D/YYYY in America/Denver.

Write action note
Start ITP started L073028-ITP · template ITP_Generation_Revised_2
Header field ITP header changed; ITP plan no. changed for no client: ACME; the new number for no
Line approved ITP line 1.3 approved after NCR NCR-2026-0021 when the line was rejected before
Line unsigned ITP line 1.3 initial removed was Quinn QC 10/17/2026
Line details ITP line 1.3 updated the changes joined by , : marked N/A, applies again, customer code W, customer code as template, customer Rick Inspector, customer cleared, customer date 10/17/2026, note
Line rejected ITP line 1.3 rejected NCR NCR-2026-0021 · <note> or NCR # pending · <note>
NCR entered later ITP line 1.3 NCR number entered NCR NCR-2026-0021
Section N/A ITP section 5 marked N/A, ITP section 5 applies again the section title
Block fields ITP block 3 QN # changed, ITP block 3 remarks changed the value
Block signed ITP block 3 signed Sections 1–3 or Section 4
Block unsigned ITP block 3 signature removed
Customer complete ITP block 3 customer complete recorded, ITP block 3 customer complete cleared Rick Inspector (the cleared name on a clear)
Sign-off ITP signed off PDF filed
Reopen ITP reopened the reason

A Q.C. folder document writes an audit row qc_doc.add or qc_doc.revise (subject qc_doc), with doc_id, project_id, unit_id and replaces in the detail, detail.text Q.C. document added or Q.C. document revised and detail.note L670 · WPS / PQR · WPS-101 GTAW/SMAW Rev 2 · wps.pdf.

Phase 7: close, file, PDFs and prints

Nothing in the rule table changes in phase 7. FILE, ADMIN_REOPEN, SET_VCLOSED and SET_DATABOOK_AT keep their rows.

Close in VISUAL

SET_VCLOSED is Clerical, in status complete, only when the packet is routed to the data book (POST /api/packets/{id}/vclosed {closed}). Confirming sets vclosed_at and vclosed_by. Taking it back clears both ("Not closed in VISUAL, move back"). A packet routed to Shipping files without it.

The packet read carries vclose_check, outside the seal. It is null for a hand packet. For a feed packet: observed_at and closed_at from the feed's VISUAL state, open_wos (the legs whose status is not C and not cancelled, as wo_base/lot text, never cast), and agrees (true when the Clerical confirm and the feed's closed state say the same). The feed state is a hint. Clerical's confirm is the record, and the precondition vclosed_if_databook reads only the confirm.

Filing

FILE is Clerical, from complete, held by an open change order, signed ("File in the data book"), with the precondition vclosed_if_databook ("Close the job in VISUAL first.").

When vclose_check.open_wos is not empty, the transition must carry confirm_open_wos: true. Without it the answer is 409 open_work_orders "VISUAL still shows 2 work orders open on this packet: L489052/1, L489052/2. File anyway?" with work_orders in the body. It is a warning, not a block, on both routes. The check runs after the policy and before the signature, so a cancelled confirm costs no PIN attempt. With the confirm, the seal keeps the work orders in open_wos and the log note says so. A hand packet has no feed state and no warning.

In one transaction, filing sets status filed and databook_at, writes the seal, builds the data book, stores it as an asset on the seal, and writes the log and audit rows. A data book that cannot be built answers 500 databook_failed "The data book could not be built: . Nothing was filed." and nothing is written. A part that cannot be read (a missing file, an unreadable MTR) does not fail the filing: it becomes a warning row in the data book index.

The filed lock

A filed packet refuses every write except SET_DATABOOK_AT and ADMIN_REOPEN, Admin included (code filed). Reads, PDFs, the CSV and prints stay open.

The seal and reopen

The seal is HMAC-SHA256 with the server seal key over the packet's read model in seal mode. GET /api/packets/{id}/seal rebuilds the content and answers {seal, valid, seals}. valid is null when the key is not available.

ADMIN_REOPEN is Admin, from filed, with a reason of at least 8 characters and a signature ("Reopen a filed packet"). The packet goes back to complete. The seal is marked broken with broken_at, broken_by and broken_reason. The row and its data book are kept: they are the record of what was filed. Filing again writes a second seal with its own data book. The packet read shows the newest seal, broken or not, with its data book, and seals, the number of seal rows.

PDFs, the CSV and prints

Every read below needs a signed-in session and a packet that exists and is not removed (404 not_found). Every role that can open the packet may read them, PM included. No policy action guards them, and the filed lock does not apply. Each one writes a print_log row and an audit row after the bytes are built.

Endpoint What When Log kind Audit
GET /api/packets/{id}/pdf/databook The filed data book as stored, or one built now and stamped "not yet filed" complete or filed, else 409 wrong_status "The data book is built once the packet is back from Q.C." databook-export export
GET /api/packets/{id}/pdf/traveler The job traveler with the work order QR codes any status traveler export
GET /api/packets/{id}/export/traceability.csv The traceability CSV, with the formula guard any status csv export
GET /api/packets/{id}/print/{kind} A printed copy: traveler, map-h, map-w, clean, void, databook, doc databook from complete on (409); void only with void pages (404 nothing_to_print "Nothing to print."); doc only for an asset of the packet, its unit or project folder, or its filed data book (404) the kind print
GET /api/packets/{id}/prints The print log of the packet, newest first, 200 rows any status
GET /api/itps/{id}/pdf The ITP PDF built now, stamped signed off or open any status itp-pdf export
GET /api/itps/{id}/print The ITP PDF stamped PRINTED COPY any status itp print

?download=1 serves the file as an attachment. ?sheet=n limits map-h, map-w and clean to packet page n. Prints and exports write no packet_log row, because they change nothing on the packet. The History tab lists them from GET .../prints.

Log texts

The action and note of packet_log for close, file and reopen.

Write action note
set_vclosed, confirm Job closed in VISUAL the packet's work order bases, L489052, L489053, plus · VISUAL still shows open: L489052/1 when the feed shows open legs
set_vclosed, taken back Moved back to ready to close
file Filed in the data book the note given with the step, plus Filed with work orders open in VISUAL: L489052/1, L489052/2 when confirmed past open work orders, joined with ·
file, the data book Data book filed N pages
admin_reopen Reopened by IT the reason
set_databook_at Data book date set

The audit gains print (detail {kind, what, pages, stamp_sig}, plus sheet and asset_id when given) and export (detail {kind, what, pages, stamp_sig}, kind databook, traveler, csv or itp). FILE, ADMIN_REOPEN and SET_VCLOSED write their audit rows through the write pipeline as before.

Phase 8: Project Management, find bar, presence

Nothing in the rule table changes in phase 8. Project Management, the find bar filters and presence add no policy action and no write.

Who reads the Project Management endpoints

Every endpoint under /api/pm needs a signed-in session. Any role may read them, not only PS-ProjectMgmt, as every role may open every packet (open question 39). An unsigned request is 401. PM writes nothing: there is no POST, PUT, PATCH or DELETE under /api/pm, and the PM role passes no write action anywhere else. A packet opened from the PM screen shows "View only." The reports read PostgreSQL only. They never read VISUAL or M-Files.

Endpoint What
GET /api/pm/overview The scope, the KPI tiles, the summary lines, the pipeline by step, and the units late or at risk
GET /api/pm/projects?expand=all|<project ids> Projects and units, with the units of the opened projects, or every unit with expand=all
GET /api/pm/aging The pipeline and the three aging tables
GET /api/pm/hours The four hours tables
GET /api/pm/quality The five quality tables
GET /api/pm/find?sort= The cards in scope, sorted
GET /api/pm/export.csv?table=<key>|all One table, or every table, as CSV. An unknown key is 404 not_found.
GET /api/pm/report.pdf The production status report, inline unless download=1

The scope

Every PM endpoint takes the scope params: project_id, unit_id, dept, status, station_id, welder_id, flags, flag, q and period. They mean what they mean on GET /api/packets (below). period is 30, 90, 365 or all, default 90. It limits the history figures only: Q.C. rejects, filed, lead time, sent back and the step history. mine in flags is ignored on PM.

  • Projects in scope: every project not removed. A closed project only when a packet in scope belongs to it.
  • Units in scope: the project's units. When any filter other than the project is set, only the units with a packet in scope.
  • Health follows the old healthOf. empty with no packets. done when every packet is filed. late past the due date. risk when due within 7 days and under 75% done, or when any packet has an open change order or a warehouse hold. Else ok. A unit uses its own due date, else the project's. A project is as healthy as its worst unit.
  • Over target means station timer hours over the work-order target hours. VISUAL ticket hours are shown beside the timer and never decide the flag (open question 38).

q on GET /api/packets, the boards and PM. Up to 8 words, and every word must match. A word matches when any field below contains it, case insensitive. A word over 60 characters is cut. The words lot and rev on their own match everything, so "lot 52" and "rev B" work as they did in the old build.

  • The project: number, name, customer, PO and aliases.
  • The unit: the unit number (L670 and the lot) and the lot, both also with the lot's leading zeros stripped, so 52 finds lot 052.
  • The packet: op, title, drawing, rev, WPS, customer, the department name, the status label and the flag kinds. The word flagged matches any flagged draft.
  • The station name, and the assigned welder's display name and stamp.
  • The work orders: the base, and the base with the lot, split and sub (L489052/1).
  • The BOM: heat, part ID, description and material.
  • Change orders: CO-<n>, the bare number and the ECN.
  • Welds: the stamp and the welder's display name.

A child match never repeats a packet. IDs are matched as text, never cast.

Filters

The server applies the filters on every list and board (open question 41). A board never fetches more than it shows. A filter only narrows what the person could already read. It never widens access, and each board keeps its own scope checks (a supervisor's departments, the stall's station).

status takes one of the words below, or a comma list of raw statuses as before (status=ready,review).

value label packets
draft Ready to release draft
warehouse With warehouse (any stage) warehouse
ready Ready to assign ready
shop In the shop (ready to Q.C.) ready, assigned, in_progress, review, qc
station At a station (assigned / working) assigned, in_progress
review Supervisor review review
qc At Q.C. qc
complete Accepted / routed complete
filed Filed filed
open Everything not filed every status but filed

The other filters: dept (department code), station_id, welder_id (the assigned welder), project_id and unit_id (the project and unit pick), flag (the flag kind, below) and flags (the quick flags, below). The filters are joined with AND.

Quick flags and Mine

flags is a comma list.

value chip packets
co Change order open an open change order: pending, or approved with verifications still pending
short Shorts open at least one open short
overdue Project overdue the effective due date is before today
week Due within 7 days the effective due date is today to today + 7, or overdue
mine Mine the screen's own work, below

Today is the date in the site time zone (site_tz, America/Denver by default).

Mine is decided on the server from the person's AD roles and the screen they name (mine_screen), never from anything the browser keeps (open question 42). Without mine_screen it is the first screen the roles give. A board defaults it to its own screen.

Screen Mine
clerical status draft, or status complete routed to the data book
warehouse status warehouse, or an open short
supervisor the departments where the person is lead or supervisor
stall the person's shop departments and the picked station (mine_station_id). No station picked: nothing.
qc status qc
pm, or admin with no other role everything. The chip is hidden on the PM and Stall screens.

Flag kinds

flag applies to drafts only, as the flagged rule does today. The raw values (1, 0, hand_upload, a raw kind like rev_mismatch) keep working.

value label rule
any Flagged (any reason) any flag
rev Rev mismatch with M-Files flag kind rev_mismatch
unconf Rev not confirmed yet a feed draft with its drawing attached (drawing_state attached) and visual.rev_confirmed not true: the rev approval is still pending
hand Made or uploaded by hand a hand packet, or flag hand_drawing or hand_bom
none Still in drafting flag kind not_released
vault Drawing not found in M-Files flag kind not_found
read Drawing couldn't be read flag kinds lookup_failed or bad_rev
wait Drawing being looked up flag kind drawing_needed
no Not flagged no flag

Sorts

sort on GET /api/packets and GET /api/pm/find.

value label order
updated Last updated newest change first (the default)
project Project / lot project number, then lot, then op, in text order
due Due date the effective due date, earliest first, none last
status Status the workflow order
dept Department department code, then newest change first

Facets

facets=1 on GET /api/packets, and always on the shop, stall, warehouse and Q.C. boards, adds the stations and assigned welders among the packets in the project and unit pick, ordered by name. The other filters do not narrow the facets. The find bar's Station and Worker lists come from them. The KPI numbers on every home screen follow the project and unit pick only, never the other filters.

Exports

Every PM export writes one print_log row and one audit row with the action report exported, after the bytes are built (open question 39).

Export Log kind what pages
GET /api/pm/export.csv report-csv <table name> · CSV · <scope label> none
GET /api/pm/report.pdf report-pdf Production status report · PDF · <scope label> the page count

The rows carry no packet and no unit. The audit detail carries name, format, scope and period. The CSV has the formula guard on every cell, a BOM and CRLF line ends. The PDF carries the controlled-copy stamp on every page.

Presence

The packet page shows who else has the packet open: Also in this packet now: <Name> (<role>), joined with ·. Nothing is shown when the person is alone.

  • Any signed-in person sees who else is on the same packet. A presence entry is the user id, display name, role, screen, packet id and since. Nothing else (open question 40).
  • The role is the label of the screen the person has open (Clerical, Warehouse, Supervisor, Weld Stall, Q.C., Project Mgmt, Admin), else the label of their first role.
  • A locked session drops out at once. Lock and unlock publish a session event (locked, unlocked) from POST /api/auth/lock, POST /api/auth/unlock and the server's idle lock. Unlock brings the person back.
  • A revoked session drops out at once, and its stream ends.
  • Closing the tab or losing the network drops the person out when the stream ends, within the stream's ping cycle (25 seconds). No other idle rule is needed.
  • The server also keeps who is on each screen. Phase 9's Admin "Who is in" tab reads it (GET /api/admin/presence).

Tightenings against the old build

What the old build allowed What the rebuild does Why Can be vetoed
The find bar filtered in the browser, over every packet the browser had loaded. The server applies the search and every filter on each list and board. A filter only narrows what the person may read. A board never fetches more than it shows. No
"Mine" was worked out in the browser from the local session's role. Mine is decided on the server from the person's AD roles and the screen they name. The stall's Mine needs the picked station. The roles come from AD, not from what the browser keeps. Yes
PM exports were built and saved in the browser, and the browser wrote the report exported log line. Every export is built on the server and logged in print_log and the audit as report exported, with the scope, the period and, for the PDF, the page count. The browser alone could skip the log. Yes
The PM reports were on the PM home screen only. Any signed-in role may read them, as any role may open any packet. PM still writes nothing. The figures come from the same packets every role can already open. Yes
Each browser published its own presence, with the name, employee ID, role and stall, refreshed every 20 seconds. The server builds presence from the session: display name and role, no employee ID. A locked or revoked session drops out at once. Presence shows only what it needs, and a locked screen is not someone in the packet. Yes
Over target was worked out in the browser from the hours it had. Over target is timer hours over the work-order target, on the server. Ticket hours are shown beside it and never decide it. The station timer is the clock of record (open question 1). Yes

Phase 9: Admin, notifications, reconcile

Nothing in the packet rule table changes in phase 9. The new endpoints are Admin endpoints and one Account endpoint. None of them writes a packet.

Who may use the Admin endpoints

Every endpoint under /api/admin needs an Admin (PS-Admins) in a password session. An Admin in a PIN session is 403 password_session_required. Every other role is 403. An unsigned request is 401. Every write also passes the Origin check and the body limit. Tests try every endpoint as every role.

Endpoint What Audit
GET /departments Every department, its AD groups (and whether each is in the OU; unknown when AD is down) and its stations none
PATCH /departments/{code} Name, active, stations (rename, reorder, add, hide) admin.department_updated
POST /departments A new shop department with its stations; answers the three group names IT must create admin.department_added
GET /users, GET /users/{id} Gain the welder stamp, profile_active, station limits and the directory flags none
PATCH /users/{id}/profile Welder stamp, profile_active, station limits per department admin.profile_updated
POST /users/import The profile CSV, as a preview (apply: false) or applied admin.profile_updated per changed person, admin.profile_import
GET /checklists, PUT /checklists The weld and plain station checklists admin.checklists_updated
GET /security/settings, PUT /security/settings The session, lock and sign-in limit settings admin.security_settings_updated
GET /security/alerts?hours= Security alerts for 1 to 168 hours none
GET /security/integrity The newest finished integrity run and its findings none
GET /access-log Sign-in attempts and identity audit rows for everyone none
GET /access-log.csv The same, as CSV, at most 50,000 rows admin.access_log_exported, a print_log row of kind access-log-csv
GET /presence Live sessions, locked or not, with the screen and packet none
POST /stamp-verify, POST /stamp-verify/pdf Checks a stamp line, a 16-character code or a PDF (25 MB) against the print log admin.stamp_verified
GET /directory-flags Active users with no employee ID, and employee IDs on more than one account none
POST /ad/refresh Asks the worker for an ad-reconcile run; 202 (open question 48) ad.refresh_requested
GET /ad/reconcile The newest finished reconcile run and its report none
GET /notifications Mail settings, the subject prefix, every rule with its recipients, exclusions and last message none
PUT /notifications/{event_type} One rule: on or off, delivery, digest time, its hours or days, recipients, exclusions admin.notification_rule_updated
GET /notifications/groups?q= AD group search (2 to 100 characters; 503 when AD is down) none
POST /notifications/{event_type}/test A test message, to the rule's recipients or to one address admin.notification_test
GET /notifications/sent The sent log none

Every Admin change is audited, with the state before and after where there is one.

Compare and set

The checklists, the security settings and each notification rule carry a version. A save sends the version it read. When someone else saved first the answer is 409 version_conflict with the current value, and nothing is written. The screen reloads and says so.

Departments

  • The code and the short name (the slug) never change. They are in the AD group names. A trigger refuses a change, and a PATCH body that names code or slug is 422.
  • Stations are never deleted. Station limits, packets and history point at them. A station is hidden by setting it inactive. A station listed without an id is added. A station missing from the list is left as it is. Two stations of one department with the same name are refused (422 duplicate_station).
  • A new department needs a code of 2 to 4 capital letters or digits and a short name of 2 to 31 letters or digits starting with a letter, both unused (409 code_taken, slug_taken). Only shop departments can be added; a support department is 422 support_fixed, because the support roles are fixed (open question 49). The answer names the three groups IT must create. Until they exist the department has no people.
  • After a change the app rebuilds its group map from the departments table. The worker reloads it at the start of every reconcile and role refresh run.

Profiles

  • The welder stamp is 1 to 12 letters, digits or dashes, unique among users ignoring case (409 stamp_taken). Empty clears it. The packet's own welder stamp field still allows 10; the profile stamp is copied onto the packet as it is.
  • profile_active off hides the person from the welder picker and the worker filter. It does not change their roles or what they may do, and an assign sent to the API still checks only the role (open question 45). AD decides who may do what.
  • Station limits are set per department. A station must belong to that department. An empty list clears the department's limits.
  • The CSV import matches employee IDs as text among active users. 0042 is not 42. Columns: employee_id (required), welder_stamp, active, stations (<dept code>:<station name> joined by ;, the person's whole list; open question 50). An empty cell leaves the value. - clears it. Up to 2,000 rows and 1 MB. Each row lists its changes and its errors: unknown employee ID, an ID on more than one user, an ID twice in the file, a bad or taken stamp, a bad active value, an unknown department or station. Apply with any error is 422 with the same rows and changes nothing. Otherwise every row is applied in one transaction.

Checklists

Both lists need at least one item and at most 40. A key is lower case letters, digits and underscores, starting with a letter, at most 30 characters, unique in its list. Group and text are not empty, at most 200 characters. The only placeholders are {drawing}, {rev} and {wps}. Answers on open stages are kept by key. A removed item drops out of new checklists only. An item added while a stage is open must also be ticked on that stage before submit, since the completeness check reads the live list.

Security settings

Stored as the security settings row over the environment defaults. A value out of its bounds is refused (422 bad_settings), and a stored value out of bounds is ignored. The keys and bounds are in SECURITY.md, "Security settings (phase 9)". A save applies in the app within 30 seconds. The PIN and step-up failure limits (5 and 3) stay environment settings.

Access log, presence and the stamp check

  • The access log shows every person's sign-in attempts (successful and failed) and their auth.*, pin.*, device.* and sig.* audit rows, as the Account access log shows a person their own. The address filter takes an address or a range. Request bodies and secrets are never in it.
  • Who is in shows live sessions (not revoked, not expired) seen within the idle minutes that apply to each. The screen and packet come from the event stream, matched by person.
  • The stamp check never trusts the text. It finds the 16-character signature, looks it up in print_log, recomputes it with the seal key from the logged row and compares the text with the logged stamp line. It answers genuine, does not verify (the signature or the text differs from the log), or not found.

Notifications

  • An Admin edits every rule. Recipients are any AD group under the base DN, a user, a mailbox, or (for the department events, co_waiting and qc_reject) the Supervisor group of the event's department. At most 50 recipients and 200 exclusions per rule.
  • An Admin may leave people out of a rule (an exclusion), except on the security event types: security_alert, signin_burst and integrity_failure. An exclusion on those is 422. Nobody can be left out of them (open question 46).
  • A test send goes at once, from the app, even on a stack in dry run. With an address it goes only there.
  • Recipients are resolved when a message goes, not when the rule is saved: group members (nested, enabled accounts with mail), a user's address while the user is active, a mailbox as typed. An exclusion drops the person by user and by their address.

Account notifications

Endpoint Who What
GET /api/account/notifications Any signed-in, unlocked session, PIN included Each enabled event type: whether it reaches the person and why (user, mailbox, group <name>, Supervisor group of <code>, left out by an Admin, directory unavailable), and whether they opted out or may
PUT /api/account/notifications/{event_type} The person, in a password session {opt_out}. Writes or removes their own exclusion. 403 for a security event type. Audit account.notification_opt_out when something changed

A person's own opt-out is kept when an Admin saves the rule. An Admin's exclusion is not removed by the person.

Security events

The three security event types (security_alert, signin_burst, integrity_failure) have no opt-out and no exclusion. An Admin can still turn the rule off or change its recipients, on the record.

  • security_alert: an account cooldown started, a PIN disabled after five wrong attempts, or a session ended after three wrong PINs or passwords at unlock or signature. One per account or person per 15 minutes.
  • signin_burst: one address over its failure limit, or failed sign-ins across accounts in 5 minutes at or over signin_burst_threshold (default 20). One per address, or one for the burst, per 30 minutes.
  • integrity_failure: the integrity job found a problem. Cleared by a clean run.

Audit rows added in phase 9

  • policy.denied: a 403 after a person was known. Method, path and code only, never a body or query string. One per person, method, path and code per minute.
  • auth.lockout: an account went into its cooldown. auth.signin_burst: an address over its limit, or a burst across accounts.
  • auth.session_ended with {reason, by} for every session the reconcile or the role refresh ends (ad_disabled, ad_gone, roles_lost).
  • The admin.* rows in the table above, ad.refresh_requested and account.notification_opt_out.

Tightenings against the old build

What the old build allowed What the rebuild does Why Can be vetoed
The Admin page added a department with any typed code, shop or support, and changed a department's stations as a comma list, so a station could disappear. Code and short name are checked and never change. Only shop departments are added. Stations are never deleted, only hidden. The three AD group names are shown before the save. The code and short name are in the AD group names, and limits and packets point at stations. Yes
A welder stamp was set in the Admin user sheet, checked in the browser, 1 to 10 characters, not unique. The stamp is checked on the server, 1 to 12 characters, unique among users. Two welders with one stamp break the weld record. Yes
Users, levels and departments were edited in the Admin page. Roles come only from AD groups. The Admin edits only the profile (stamp, profile active, station limits). Turning a profile off hides the person from pickers and changes no right. AD is the one place access is granted. No
The security alerts panel and the integrity check ran in IT's browser when Admin was opened. Both run on the server: alerts from the audit and the sign-in attempts, the integrity check every night in the worker, with an email alert. A check that runs only when someone looks finds problems late. No
Nothing was emailed. Events go by email through app-03 to rules an Admin sets. Security events cannot be turned off by the person or excluded by an Admin. A security alert that can be muted is not one. Yes
The access log export ran in the browser. The CSV is built on the server with the formula guard and logged in the print log and the audit. The browser alone could skip the log. No
A stamped copy could be checked only by eye. The stamp check recomputes the signature with the seal key and compares the text with the print log. A copy is genuine only if the server says so. No

Worker writes (phase 3)

The worker has no session. It writes through the same policy as a person, as the system principal Principal(user_id=None, system="visual-feed"). Each write locks the packet row (FOR UPDATE SKIP LOCKED; a row locked by someone else is left for the next run), builds the packet state, runs policy.check(), makes its change, bumps version, and writes a packet_log row (by nobody, by name "VISUAL feed", role system), an audit row (packet.<action>, role system) and a change event. See FEED.md for when each write happens.

Action From What the worker does
vis_update_draft draft Updates a draft made by the feed: work orders, BOM (unless uploaded by hand), drawing and rev, dates, flags, drawing pages from M-Files.
vis_retire_draft draft Soft-removes an untouched draft whose work orders all moved to another packet, reason moved.
vis_open_co any but draft and filed Opens, re-aims or withdraws the packet's one pending feed change order, stages a drawing on it, and records drawing flags on a packet past draft.
vis_auto_release draft to warehouse Sends a ready draft to the warehouse. Same preconditions as send_to_warehouse (heat map answered, drawing attached). The feed only picks drafts with no flags and the rev confirmed by the drawing job.

What the feed may write:

  • Drafts it made, in place, through vis_update_draft and vis_retire_draft.
  • New drafts, projects and units (created_by null, audit role system).
  • The order-derived fields of projects and units, only where the value came from VISUAL. A value Clerical typed is never overwritten.
  • On packets past draft: only a change order (vis_open_co), the observed VISUAL state (leg statuses, closed, cancelled, work order gone, ticket hours) and the drawing flags.
  • Its own tables: the caches, drawing_lookups, the job tables.

What the feed may never write:

  • Shop-side tables: stages, welds, heat tags, checklists, the clock, warehouse pulls and shorts, Q.C. records, seals. In-shop packets only get a change order.
  • A removed packet. A key whose packets are all removed is never made again.
  • A filed packet.
  • Any person's action. The system principal passes only the vis_* actions, and people can never take them.
  • VISUAL or M-Files. Both libraries are read-only.

Rev approval

When M-Files has a different released rev from VISUAL, the drawing job stages the M-Files copy. A Clerical Supervisor (PS-Clerical-Supervisor) can approve it on a draft with rev_approve: a reason of at least 8 characters and a signature ("Approve the M-Files revision"). The pages are attached and the approval is kept on the packet (visual.rev_ok). With nothing staged the answer is 409 nothing_staged.

VISUAL is the source of truth for the rev. When M-Files holds the rev VISUAL calls as Effective or Retired, the drawing job attaches it to the draft with no flag, so there is nothing for Clerical to approve (see FEED.md, the decision table). rev_approve is only for a mismatch where M-Files has no usable copy of that rev. Packet Station never attaches a drawing at any other M-Files status. A packet whose visual.rev_ok has use: "called" (Clerical kept the rev VISUAL calls by hand, in the build before this rule) keeps it: that rev is now used anyway.

Hand uploads on flagged drafts

On a draft made by the feed that is flagged (or already has a hand upload), Clerical can upload a drawing (edit_document_set) or a BOM (edit_bom) by hand. Both need a reason and a signature. A hand drawing sets drawing_state hand and flag hand_drawing; a hand BOM sets flag hand_bom and the feed stops replacing the BOM. An unflagged draft refuses with 409 not_flagged. Auto-release never takes a hand-flagged draft, so a person sends it on. "Use VISUAL's BOM again" removes the hand BOM.

Change orders from the feed

  • A pending feed change order holds nothing, unless Clerical puts it on hold (co_hold_toggle). Then it blocks the held steps until released or decided.
  • Approval (co_approve, Clerical, signature) applies the staged change to the packet: work orders, BOM, drawing and rev. When the drawing changed, the new drawing must be staged first (co_staged_if_dwg_change, 409 co_not_staged). The old drawing pages are voided, not deleted.
  • After approval a major change order asks the departments it touches to verify (co_verify), and holds the packet until they have.
  • A minor change order (only target hours or the want date changed) needs Clerical approval only. No department is asked to verify, so it holds nothing after approval.
  • Rejection (co_reject) needs a reason and a signature. The feed does not reopen a change order Clerical rejected for the same target.

Tightenings against the old build

The old policy was looser than the old screens in places. The rebuild follows the screens where they were stricter, and the README where it states the intent. Each row is a change Seth can veto.

SethD answered on 2026-10-26: every row is kept as shown (Gitea issue 6), and he confirmed the data book date (issue 14), the withdrawn verification and ITP initials rows (issue 15), both release rows (issue 16) and the block signature row (issue 26).

What the old build allowed What the rebuild does Why Can be vetoed
A department lead could write welds, BOM, heat tags, the checklist, stage fields and the clock through the policy whenever the packet was in a shop status. These edits need the holder of the packet (the holder rule, applied as the old screens did). A lead of another department cannot. The screens only offered these to the holder. The policy now matches. Yes
Any worker in the department within their station limits could start or submit a packet (worksOn ignored who was assigned). START and SUBMIT need the assigned welder for a worker. Leads and supervisors still can. The README says only the assigned worker. Yes
A status change could carry any other field in the same save. A transition carries only its own fields (the step's inputs). Other changes go through their own edit actions and rules. One rule per write keeps the check honest. No
Clerical "lead" actions (approve an M-Files rev mismatch, move back from VISUAL review) were open to any Clerical member with a lead flag. REV_APPROVE and moving back from VISUAL review need Clerical Supervisor (PS-Clerical-Supervisor). There is no Clerical lead AD group. Yes
A packet routed to Shipping had no path to filed. Complete packets routed to Shipping get the same Clerical close and file path. Only the Data Book route needs the VISUAL close before filing. Shipping packets were stuck at complete. Yes
Anyone could set the data book date, even on a filed packet. SET_DATABOOK_AT is Clerical or Q.C. only (open question 17). It stays allowed on a filed packet. The data book date is a Clerical and Q.C. record. Yes
Change-order verifications were stored in the packet document, with no rule against changing them later. Verifications need a signature, are insert-only and cannot be withdrawn (open question 18). A signed verification is a record. Yes
The old policy did not look at the BOM when the warehouse released a packet. WH_RELEASE needs every BOM line not marked n/a to be pulled or to have an open short. A packet should reach the shop with its material, or with the shorts on record. Yes
The old screen asked for a heat number on every pulled line before release, but the policy did not check it. WH_RELEASE also needs a heat on every pulled line that issued pieces, unless the line is N/A or a sub-assembly (heats_recorded), checked on the server. Traceability is the point of the pull. The screen alone could be skipped. Yes
Hold reasons and short reasons were any text the screen sent. Both are closed sets checked on the server. "Other" on a hold needs a note. The board and the shorts table group and report on the reason, so it must be one of the list. Yes
A hand draft could leave Clerical with no drawing (the packet PDF upload stood in for it). A hand draft needs a drawing attached before any send from Clerical. There is no packet PDF upload in the rebuild. Yes
Attaching drawing pages by hand needed no signature. Attaching a drawing by hand needs a signature ("Attach a drawing by hand"). It replaces what M-Files would supply, so a person stands behind it. Yes
Admin could write anything on a filed packet with an IT reason. Admin cannot write a filed packet except through ADMIN_REOPEN (with a reason and a signature), and SET_DATABOOK_AT. A filed packet is sealed. A change breaks the seal on purpose, on record. No
Admin passed every check after the change-order hold, so an admin could make a step from any status. Admin goes through the same status check. The bypass covers who and custody only. Preconditions still apply. Admin fixes data, not the workflow order. Yes
A hand drawing or BOM upload on a flagged VISUAL draft took a reason of 3 characters and a PIN sign-off checked in the browser. Both need a reason of at least 8 characters and a signature verified on the server, kept on the packet with who and when. A hand upload stands in for VISUAL or M-Files, so a person stands behind it. Yes
Approving a different M-Files rev was open to a Clerical lead. rev_approve needs Clerical Supervisor, with a reason and a signature. There is no Clerical lead AD group, and the approval overrides VISUAL. Yes
The Sync on a Clerical PC skipped removed packets ("removed here, not re-made"), but only as the browser saw them. A removed packet's key is never recreated, whatever VISUAL says. The match runs on the server across live and removed rows, in the feed's transaction. A removal is a decision. The feed does not undo it. No
The Sync saved through the same packet document that held the shop's work, so nothing but the code kept it off the shop's fields. The feed never writes shop-side tables. Packets past draft only get a change order, observed VISUAL state and drawing flags. The shop's record is the shop's. No
The assign sheet only offered welders of the department and filtered the stations by the welder's limits. The policy checked neither. ASSIGN checks on the server that the welder has a shop role in the packet's department, and that a limited worker's station is one of their stations. The picker alone could be skipped. Yes
The old screen asked for a weld of the current department before submit, but the policy did not check welds. welds_recorded counts the welds of the packet's current department, on the server. After a route the new department marks its own. Each department records its own welds. Yes
A mark could be placed on a VOID sheet. A VOID sheet refuses new marks and moves (422 void_page). The marks already there stay. Marks belong on the current revision. Yes
The station clock ran in the browser, and the elapsed time was saved from the browser. The server keeps the clock with the database time. No request sets the elapsed time. The clock is a record. A browser clock can be wrong or changed. No
Packet document kinds and Q.C. folder document types were whatever the screen sent. Both are closed sets checked on the server (and by a CHECK in the database). The data book sorts and labels by kind and type. Yes
A packet document could be taken out of the data book with no reason. A take-out needs a reason of at least 3 characters. The row is kept with who, when and why. A document leaving the record is a decision on record. Yes
A Q.C. reject took any non-empty text. A reject needs a reason of at least 8 characters, or a well-formed NCR number, or both (open question 27). A short note like "no" says nothing to the supervisor. An NCR number points to the full record. Yes
An ITP line rejected without an NCR could not be approved only because the screen disabled the button. The server refuses the approval until the NCR number is entered (409 ncr_required). The screen alone could be skipped. Yes
ITP block signatures and the sign-off were PIN checks in the browser. Both are signatures verified on the server and stored with a content hash. A signature is a record. No
The ITP sign-off was offered when the screen saw every block signed. The sign-off is a server rule: every block signed (409 blocks_unsigned), and a complete ITP refuses every write but the reopen. The screen alone could be skipped. Yes
The screen limited removing an ITP line's initials to the same inspector or an admin, and refused it while the block was signed. Nothing else checked. The server enforces both (open question 18). The initials are that inspector's record. The screen alone could be skipped. Yes
Any Q.C. user could remove a block signature. Only the signer or an admin, while the ITP is open (open question 30). A signature is that person's record. Yes