On a page replacement only the heat table placement is copied to the new page; welds and heat tags stay on the VOID page.
Built as the default: the manual copy button is not ported.
To answer: whether the shop wants it back.
Plan reference: Q25 in docs/PLAN.md (open questions). Answer here; the build takes the default until then.
On a page replacement only the heat table placement is copied to the new page; welds and heat tags stay on the VOID page.
**Built as the default:** the manual copy button is not ported.
**To answer:** whether the shop wants it back.
---
Plan reference: Q25 in [docs/PLAN.md](https://gt.pescoinc.biz/spencerm/PacketStation/src/branch/main/docs/PLAN.md) (open questions). Answer here; the build takes the default until then.
Yes leave as is. if there is a change order, the work must be re verified through the department. There will be situations where the change order may drastically change something that can't just be copied over
Yes leave as is. if there is a change order, the work must be re verified through the department. There will be situations where the change order may drastically change something that can't just be copied over
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
On a page replacement only the heat table placement is copied to the new page; welds and heat tags stay on the VOID page.
Built as the default: the manual copy button is not ported.
To answer: whether the shop wants it back.
Plan reference: Q25 in docs/PLAN.md (open questions). Answer here; the build takes the default until then.
Yes leave as is. if there is a change order, the work must be re verified through the department. There will be situations where the change order may drastically change something that can't just be copied over
Kept as built and recorded in docs/PLAN.md (PR 51). Nothing changes in the build. Closing.